We have tested 3/4" 800 globe valve upto 225 kg/cm2. (The purpose was to make testing assembly that can test upto 140 kg/cm2. As we have no availibility of 1500 rating valves). There was no leakage through glands and bonnet flange. The valve was tested in open and close conditions. The question...
Thanx METENGR for immediate reply...
We are repairing by our own means,However from all the above discussion BLIND FLANGE material seems to be acceptable for plugs. Does API 510 allows forged flange material for plug material??????
METENGR.. The material of Tube sheet is A-765-2, E-2002 and E-3002 basically the tags of Heat Exchangers.
EDSTAINLESS... Basically we are at the verge of Turnaround.. 2205 material bars are on order but i think ETA could not be possible before Turnaround.
Yes STANWELD... We will seal welding...
We have a spare BLIND FLANGE of SA-182 F51 UNS NO. S-31803 (DUPLEX). Material of tubes of E-2002/E-3002 and E-3801 is A-789 UNS No. S-31803 that seem compatible with BLIND FLANGE material. Can we use Blind Flange material to prepare plugs for our exchangers?
THANKS metengr..thats what i was expecting...
RMW.. The welding of the plug is on tube seal welds. We do not touch tubesheet for welding purpose..
THANKS again
CAN WE USE SS316L PLUGS TO WELD ON A-789 S31803? FOR WELDING WHAT FILLER WIRE TO BE USED? CAN WE USE ER-2209?
INFORMATION WOULD BE APPRECIATED.
REGARDS
We have duplex material installed at our oil and gas plant. some days ago when our PLATE TYPE HEAT EXCHANGER (exchanging heat between rich and lean amine) efficiency went down, we open it. deposition of carbon observed with some hard scales. Sample was analysed in lab and the result was high...
Thanx for answering metengr.
This is LEAN AMINE TRIM COOLER.Cooling water in tubes while amine solution is toward shell side. The material for tube sheet is A-266 cl2.