Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by jsi1612

  1. jsi1612

    Efficiency of Natural Gas Transport through Pipelines

    One other piece of info from a macro perspective: I went to a natural gas company's website and got this info from their company fact sheet. Their total compressor station horsepower: 840,000 hp Their total system design deliverability: 4,500 mmscf/day Again assuming a natural gas combustion...
  2. jsi1612

    Efficiency of Natural Gas Transport through Pipelines

    1969grad and jsummerfield Thank you for your replies As a follow-up I consulted a midwest based natural gas pipeline company. A helpful gentleman provided this example of natural gas transmission. Length of pipe: 100 miles Inside diameter: 29 inches Pressure: 1000 psi starting, once dropping...
  3. jsi1612

    Efficiency of Natural Gas Transport through Pipelines

    Hello, I am an electrical engineer employed by an electric utility. I was wondering how much energy it takes to transport natural gas through a typical size gas pipeline used in interstate transport of natural gas. Assume no gas is leaked. It is my understanding in gas transport, the energy...