I have found that if I open the higher assembly then open the sub assembly with errors from the higher assembly and rebuild it in its own window then go back to the higher assembly window, SolidWorks will prompt me to update. If I check yes the rebuild errors go away.
The rebuild errors are in the sub assembly. If I open the subassembly in its own window there are no errors at all. Well I just converted lightweight to resolved and for some reason this time it eliminated the errors. I have been trying that tactic for 2 days and it hadn't worked. Thanks for...
I have a subassembly which shows rebuild errors while in the next higher assembly. When I open the subassembly it shows no error. Also when I conduct a mass properties execution I recieve no data except for the location of the CG. Has anyone run into this before. I have cleared my temp file...