I have pressurized (~360 psig) hot (~280C) water which I have captured in my process. I am looking to generate steam with it (~290 psig). Can someone recommend me a company that deals with this kind one off systems.
I am apologies if this is repeating thread. Something seems didn't worked out...
Thanks Rmw for your reply.
My experience is the same, i.e. more "A" cases rather than "B".
Btw, can you recall what heat recovery was in those cases?
I am doing a utilities system efficiency check where Eco giving 20-23deg.C heat recovery and flue gases leaving the stack stay ~170-190 deg.C...
Would like to hear opinons on what is the most common scenario when installing Boiler Feed Water Economizers:
A: Deaerator-->Eco-->Boiler
B: Degasifier-->Eco-->DA-->Boiler
Thanks in advance.
I_mak
Rmw:
Indeed it does help a lot. Appreciate this very much.
Last question, what about returning condensate. In our existin unit we had it returning into the dome tray section. How's done normally? In pressurized units?
Thanks.
I_mak
I_mak
Thank you very Rnw.
I thought to include some particulars in my original note, I guess I should of...
Our condensate return vs. make-up ratio is 46% make-up/54% condensate. Condensate back to DA is about 230F. Make-up water is softened prior.
7 ppb dissolved oxygen is what I understand...
Dear Colleagues Eng's:
Looking for expert opinion on what type of Deaerator to use in food processing plant environment?
Tray or spray type? Pressure or atmospheric?
I'm replacing existing tray type, but can't get any unbiased advice from manufacturers.
Appreciate everyone’s thoughts.
Rgds...
In general. Wondering about installation tips etc. to deermine a right sized unit. What else is important except line size and steam pressure?
Thanks!
I_mak