Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by codeeng

  1. codeeng

    Double Wall Tanks

    More like a jacket but could be either to satisfy secondary containment. Apparently this is more common in Europe, not so much in Canada.
  2. codeeng

    Double Wall Tanks

    Thanks MJC I totally agree, its seems so stupid, but our client wants to know the cost delta and I'm struggling to find a vendor that could provide costs. I'm thinking 70 - 80% more. Would this sound about right?
  3. codeeng

    Double Wall Tanks

    Could anyone recommend a tank vendor with experience in double wall API650 tanks (30 to 70m diameter). Project is located in Canada. Thanks in advance.
  4. codeeng

    B7M Versus B7 Bolting

    The former is correct since the latter has been verified a million times over. If you were experienced in flange design you would already know this.
  5. codeeng

    B7M Versus B7 Bolting

    B7M bolts can be used without any analysis on standard flanges. These are intermediate strength per B16.5 Table 1B.
  6. codeeng

    Deficiency Report for Transitions (Appendix 1-8 (b) or (c))

    Thanks for clarifying that Tom. But nobody looks at the calcs anymore just the deficiency report!
  7. codeeng

    Deficiency Report for Transitions (Appendix 1-8 (b) or (c))

    Good catch Doc. I always wondered why this distance came out so small.
  8. codeeng

    Vacuum test

    There is no Code requirement for vacuum testing, just a design method.
  9. codeeng

    PD Pump to Heat Exchanger, where should Relief valve go?

    Piston pumps normally come with integral relief valves. Would this solve your problem?
  10. codeeng

    Mechanica stress problem

    The deflection of a particular section is a function of how the load is acting (uniform, concentrated, etc), the method of end supports (fixed, supported, etc) and the strength of the section under consideration (modulus of elasticity and moment of inertia). For simple beam theory and some...
  11. codeeng

    Manway size

    Seems a little silly to have such a large manway for such a small vessel. What's the reason, large removable internals? There is no Code limit in size but generally 24" would be a refinery standard.
  12. codeeng

    Equivalent Standard to AS 2129

    Definitely not compatible. As I remember AS 2129 was based on the old BS 10 flanges. You should obtain a copy of AS 2129 for pressure/temp ratings. See attached link for AS 2129 dimensions. http://www.tubesalesqld.com.au/flanges.html
  13. codeeng

    Carbon steel fittings material spec question

    Read A234 carefully. You need to select a "starting material" from Table 1. This implies to me that A234 is not a material spec as such.
  14. codeeng

    Carbon steel fittings material spec question

    Any material that conforms to Table 1 in A234 can be used. I seem to remember in the older editions they used to list acceptable materials and A106-B (for WPB) was one of them.
  15. codeeng

    Internal Painting of a L.P. Vessel

    Typically any surface coating inside or outside should exclude gasket contact surfaces.