Thanks MJC
I totally agree, its seems so stupid, but our client wants to know the cost delta and I'm struggling to find a vendor that could provide costs. I'm thinking 70 - 80% more. Would this sound about right?
Could anyone recommend a tank vendor with experience in double wall API650 tanks (30 to 70m diameter). Project is located in Canada. Thanks in advance.
The deflection of a particular section is a function of how the load is acting (uniform, concentrated, etc), the method of end supports (fixed, supported, etc) and the strength of the section under consideration (modulus of elasticity and moment of inertia). For simple beam theory and some...
Seems a little silly to have such a large manway for such a small vessel. What's the reason, large removable internals? There is no Code limit in size but generally 24" would be a refinery standard.
Definitely not compatible. As I remember AS 2129 was based on the old BS 10 flanges. You should obtain a copy of AS 2129 for pressure/temp ratings. See attached link for AS 2129 dimensions.
http://www.tubesalesqld.com.au/flanges.html
Any material that conforms to Table 1 in A234 can be used. I seem to remember in the older editions they used to list acceptable materials and A106-B (for WPB) was one of them.