Hi,
I have calculated the water hammer effect, and I have 500 psi (delta P), more my normal operation at the inlet valve (550 psig), my pressure can increase to 950 psig in my worst case. Also, I have calculated my closing time and I got 7 sec.
(with Joukowski's equations).
If my...
Hi PAN,
-What is your required flow rate? in the future 1400 m³/hr
-How about the velocity in your line size 10" or 12" in other sections? @1400 m³/hr, we'll get about 17 and 25 ft/sec.
Anyway, I have called the manufacturer and he told me that the "extreme" velocity limit is about 50-60...
Hi everyone,
I'm looking to find the maximum velocity that I can have in a hose...Someone has an idea about that?
I have found that the maximum velocity for 8 inches hose is 15 meters/second, but I bet that for gasoline, the velocity must be lower...( presence of electrostatic charge...
Humm...I have already looked API2350, but I didn't find anything about the overflows...
However, I have took the Kindsvater-Carter equation...Do you think that is good way?
http://www.lmnoeng.com/Weirs/RectangularWeir.htm
Regards,
Ken