Hi,
Can anyone please explain how to interpret the results obtained from display/diaphragm forces? I am getting a mixture of positive and negative forces at different nodes of the same floor for wind load applied in 'Y' direction, which doesn't make much sense to me.
Will appreciate if...
Has anyone done a sequential analysis with ETABS 2016 16.2.0 ?
It lakes a lot longer and eventually crashes. This model used to work fine with earlier versions of ETABS 2016.
Thanks
thread507-319174
Hi,
This thread is a continuation to the thread above.
I have designed the slabs as simply supported and want to connect them to jumpformed wall using central inserts.
Do I need to use equivalent number of centrally placed inserts to match my bottom bars? What do I need to...
thread802-349319
On the Thread above regarding modelling precast shear walls in ETABS It reads:
"1. Model the wall with shell elements roughly. In order to simulate with detail the joints, you can modify the property modifiers of the elements close to the joint only.
2. Then, after the...
Hi,
Did some hand checks this morning. Results look fine.I chose a bigger Time period for Equivalent Force Method which gave me low base shear. But still base shear from response spectrum is bigger than that obtained from ESA. That's why I was surprised at first because in all my previous...
Hi,
When looking at wall stress plots for direct stress do you guys look at top/bottom stresses or maximum stresses for reinforcement design? Can anyone shed any light on their differences?
Thanks
Thanks guys.
I have tried modelling the columns as walls. I am taking the shear force at the transition level as the diaphragm force at that level, though another engineer at my work suggests we should be taking the shear difference between this level and the level below. This would give me a...
Dear BAretired,
RCC (Reinforced Cement Concrete) is a very common term used for reinforced concrete in my country. The stairs as well as the stairs are of reinforced concrete.