The last thing i would do is call a Bystronic REP, love the machines but there people and service is a different story, i beleive i have found the problem the water lines are .125 smaller than they should be, will replace and see how she blows.....
I have a consistant chiller temp of 65.8 on my water, no errors or warnings at all on the chiller i have recently replaced one of the radiators in this machine in the HV cabinet i am not sure if it getting a good flow, our shop gets hot but if it was that i beleive every thing and both machines...
Running a Bystar 3015 my gas cabinet keeps going into HV over temp, i have a small fan i have added to it that helps but if the fan goes off it will over temp on me......Krugtech i need help